Associated Scale Services

ANYLOAD Load Cell 101BA Single Point

ANYLOAD Load Cell 101BA Single Point

Type 108BA

Accuracy class
Maximal numbers of load cell verification intervals  (nLC)

 

  C3
  5 000 

Maximal capacity (Emax) 
Minimumload cell verification interval(Vmin)

   kg
  % of Cn
  3;6;10;20;30 
  0.02
 40;50;60;100 
 0.02

Reference Max.platform size
Weight (G), approx.

   mm
   kg
  400×400
  0.3
 400×400
 0.4

Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc)
Temperature effect on zero balance (TKo)
Non-linearity (dlin) 
Repeatability (drep) 
Hysteresis error (dhy)
Creep (dDR)in 30 min.
Input resistance (RLC) [Red(+)-black(-)]
Output resistance (RO) [green(+)-white(-)]
Reference excitation voltage (Uref)
Maximal excitation voltage
Insulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range

mV/V
mV/V
% of Cn/k
% of Cn/k
%
%
%
%
Ω
Ω
V(DC/AC)
V(DC/AC)

[oF]
[oF]
[oF]

2±10%
±0.06
< ±0.0012
<±0.0040
<±0.017
<±0.017
< ±0.017
< ±0.023
415 ± 15
350 ± 3
0.5…10
15
>1[50 VDC ]
-10…+40[15…+105]
-10…+50[15…+122]
-25…+70[-13…+158] 

Safe load limit (EL)
Breaking load (Ed)

% of Cn
% of Cn

   150
   300

Protection class (IP) acc. to IEC529

     IP66

Material

     Aluminium
 Optionally      Explosion proof version (Ex ib II CT4)
 Interchangeable Products      HBM    PW6C3/PW6K
   Rice Lake    RL1521A
   Tedea    1022

download PDF