Associated Scale Services

ANYLOAD Load Cell 108TA Single Point

ANYLOAD Load Cell 108TA Single Point

Type 108TA/108TAUN

Accuracy class according to OIML R60 and NTEP
Maximal numbers of load cell verification intervals  (nLC)

   C3 / NTEP 1:5 000 class III, single cell
   5 000

Maximal capacity (Emax)
Minimumload cell verification interval(Vmin)
Reference Max.platform size
Weight (G), approx.
Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc) *
Temperature effect on zero balance (TKo)
Non-linearity (dlin)  *
Repeatability (drep)  *
Hysteresis error (dhy) *
Creep (dDR)in 30 min.
Input resistance (RLC) [Red(+)-black(-)]
Output resistance (RO) [Green(+)-white(-)]
Reference excitation voltage (Uref)
Maximal excitation voltage
nsulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range

kg
% of Cn
mm
kg
mV/V
mV/V
% of Cn/k
% of Cn/k
%
%
%
%
Ω
Ω
V(DC/AC)
V(DC/AC)

[oF]
[oF]
[oF]

5;7;10;15;20;30;50;75;100;150;200
0.02
400×450
0.33
2±10%
±0.06
< ±0.0012
< ±0.0040
< ±0.017
< ±0.017
< ±0.017
< ±0.023
415 ± 15
350 ± 3
0.5…10
15
>1[50 VDC ]
-10…+40[15…+105]
-10…+50[15…+122]
-25…+70[-13…+158]

Safe load limit (EL)
Breaking load (Ed)

% of Cn
% of Cn

   150
   300

Protection class (IP) acc. to IEC529

     IP66

Material

     Aluminum
 Optionally      Explosion proof version (Ex ib II CT4)

Interchangeable Prodcuts

     HBM    PW15/SP4
   Rice Lake    RL1042
   Tedea    1042


download PDF

scales and calibrations